Anti-static Raised Floor Characteristics
In daily life, when we ware and take off sweaters, there may cause sparks with cracking sounds. In winter, if we rub our hair hard, our hair will explode. This is static electricity. Today, we Titanflor will take you to understand the classification of the anti-static raised floor, the characteristics of the anti-static raised floor, and its applications. 1. OA network raised floor OA network anti-static raised floor is also called bare finished raised floor or office raised floor. It is composed of all steel, and the four corners are independently supported. The floor surface is treated with conductive epoxy resin electrostatic spraying, and the inner cavity is filled with foamed cement. It has strong load capacity, anti-noise, surface wear resistance, and dirt resistance. We often use them in office buildings, computer rooms, electric classrooms, etc. 2.Steel anti-static raised floor An anti-static raised floor is mainly covered with PVC/ceramics, and
Sensor Fan Assist Floor in Data Center
As we all know, the heat dissipation of equipment in the data center is particularly large. It requires a safe and reliable operating environment for equipment in the data center, including temperature, humidity, cleanliness, etc. In order to solve the challenges of high density and thermal load in data centers, Titanflor has developed a series of high-efficiency and energy-saving solutions. Sensor fan assist floor can automatically determine the on-site temperature, and make real-time reflections based on sensor signals, automatically adjust the temperature. The temperature-controlled fan is an upgrade of a function of the ordinary fan, and the scope of use on the market is becoming wider and wider. However, many people don’t know much about how the sensor fan assist floor works. So, what is the working principle of the sensor fan assist floor? How does the sensor fan assist floor work? Sensor fan assist floor is an intelligent fan system raised
Raised Floor Edge Trim
Once I talked with one client about the raised floor edge trim . I find that there’s much knowledge in raised floor edge trims. What is raised floor edge trim? There are many kinds of raised floors, we don’t say here. We can divide the anti-static raised floor into the anti-static raised floor with edge trim and the anti-static raised floor without edge trim, according to whether has the black edge trim. The edge here refers to here is the edge trim we are talking about. Although there are various raised floors without edge trim, there are more raised floors with edge trim. The edge trims are all conductive. The black conductive edge trims to ensure the anti-static function of the anti-static raised floors. And also they provide good physical protection for the anti-static raised floor edge. The advantage of raised floor edge trim Used for covering various types of
Calcium Sulphate Panel– Anti-static Raised Floor Introduction
Calcium sulphate panel is one of the most popular anti-static floors nowadays. When installing new raised floor or renovating the floor, more and more people will choose to use calcium sulfate panel. Raw material of calcium sulfate board The base material of calcium sulphate raised floor use non-toxic and unbleached plant fiber as reinforcement material. Combine with solidified calcium sulphate crystal and then pulse press the all materials. This calcium sulphate panel’s recovery rate is over 90%, which aligns with the current environmental protection and energy-saving requirements. With the increasing demand for environmental protection and energy-saving, the use and market share of calcium sulphate raised floor are rising. Usually, the bottom of the calcium sulphate anti-static raised floor is galvanized steel. And the surface covers are anti-static veneers such as HPL or PVC. The sides seal belongs to conductive rubber edge trim. You can see them widely used in computer
How to Choose The Anti-static Raised Floor?
First of all, before we choose anti-static raised floor, it is very necessary to acquaint with the condition of equipment in the computer room. After that, we can determine the type and organization of anti-static raised floor system. When choosing an anti-static raised floor, fully understand the various technical performance of the floor is important. The performance of anti-static raised floor primarily refers to its mechanical and electrical functions. 1.Mechanical properties– one factor we choose anti-static raised floor (1)Loading capacity Install the anti-static raised floor on the stringer, and then level the pedestal. The uniform load of anti-static raised floor should greater than 1000kg/m2, the concentrated load on any part of the floor should be more than 300kg. When the load is 300kg on the loading point with a diameter of 150px, the deflection should be less than 2mm without permanent deformation. Besides, the vertical loading capacity of pedestal should
Raised Floors Used for Data Center Floors
For decades, raised floors have been in huge popularity in the buildings which require information infrastructure like data centers. A raised floor in the data center floors is an uplifted floor that is designed a few inches above a concrete floor. Ideal for electrical, cooling and mechanical services, these raised floors serve the best way for creating ventilation. With the help of raised floors, the data center requires minimum energy. In addition, it maintains maximum distribution of temperature throughout the cabinets. As per the study, raised floors can considerably minimize the cooling load by 45% in commercial buildings. Luckily, with the help of advanced technology, this system when combined with AI cooling delivers tangible results. Depending upon your data center, raised floors are made from pedestals. The pedestals are then supported vertically to build the required space on the subfloor. Raised floor tiles can be made from any material such
Loading Test Method Based on CISCA of Raised Floor
Generally speaking, raised floor is becoming more and more popular in recent office using and data center. So how to choose the right panel loading is the common and important aspect before usage. Here is the CISCA loading test method for reference. We can also do such test in our testing room with machines. First , check the situation of test machine. We need to have the loading test machine with computer that can show the direct loading data in different deflection. Second, make sure the indentor is fine. It must be sure that concentrated loading shall be applied to the structure though a steel indentor 25.4mm square. And the footprint contact area should be 25.4mm*25.4mm. Finally, start the loading test after all structures are stable. Prepare 3 pieces of raised floor bare panels randomly selected, and put the whole panel on the pedestal and stringer under-structure system.
Main Types of Anti-static Raised Floor
Our common anti-static raised floor types are mainly the following:anti static tile, high pressure laminate one, steel one, composite one and so on. Anti static tile On the basis of the preparation process of ordinary ceramic tiles, the green body and glaze layer add the anti-static functional powder. It makes the ceramic tiles have a stable resistance value, generally between 1.0 x 106——1.0 x 109 Ω. And workers do the construction conveniently without laying copper strip. At present, it is very popular in the market, but there are very few manufacturers in the Chinese market. High Pressure Laminate anti-static raised floor This floor uses high-strength, fire-proof and water-proof materials as the base material, double anti-static veneer. It has excellent waterproof and moisture-proof performance and strong bearing capacity. So large and medium-sized machine rooms usually use this type of raised floor. Steel anti-static raised floor Steel anti-static floor can has several types,