Production Process of All Steel Anti-static Floor
Material selection All steel anti-static floor adopts high-quality cold-rolled steel plate. Each all steel anti-static floor needs two steel plates as basic materials. 1. Stretch All steel anti-static floor bottom plate names tensile plate. The bottom plate is made of ST-16 high quality cold rolled steel plate by stamping and drawing process. 2. Piercing After stretching, the bottom plate of all steel anti-static floor needs to be punched to prepare for the later grouting process. 3. Cut In order to produce standard all steel anti-static floor products, we need to cut the size of the steel plate according to the required size. 4. Riveting and spot welding This production step is the key step in the production process of all steel anti-static floor. By riveting and spot welding, weld the floor panel and the bottom plate together. Then the prototype of all steel anti-static floor is completed. 5. Surface phosphating

How to Wire Data Room
With the promotion of the era of big data, more and more enterprises begin to build their own data room. Some enterprises do not make reasonable planning in advance when wiring. It results in large area rework in later construction and maintenance. It is not only takes time and effort, but also increases additional costs. Therefore, when wiring the data room, we should make a reasonable plan. First, reasonable planning in the early stage A good early planning can lay a good foundation for future use. In the planning, the location that is convenient for wiring shall be selected to avoid accidents due to winding and disorderly arrangement of lines in the future. Second, detailed test After laying the cable, use professional testing tools to test the cable one by one. If any cable fails to pass the test, replaced it in time to avoid large-scale rework in the later

How to Reduce Cost Cooling in Data Center
The problem of data center cooling has become one of the top challenges faced by enterprises. Under the global advocacy of ‘green data center’, many enterprises demand to reduce the cost of data center construction, operation and maintenance. In fact, there are some simpler solutions to achieve efficient cooling effect. The cost is also lower. Straighten out the cables under the anti-static floor The overhead design of the anti-static floor can store disorderly wires. At the same time, carefully check all cables under the anti-static floor. Remove those useless cables to make more space. Use metal bracket or cable binding device to arrange the remaining cables. Then maximize the space under the anti-static floor and facilitate the air circulation. In addition, anti-static ventilation floor can be installed to improve ventilation rate. Guide the flow direction of cold air A very low-cost and innovative solution is to install some fences under

Is Related between Performance and Color of Anti-static Raised Floor?
Is there an inevitable relationship between the performance and color of anti-static raised floor? Can the anti-static raised floor with such bright colors be effectively anti-static? Let us explore the principle of it. Anti-static principle In fact, for anti-static raised floor, the most important is the conductive wire embedded in it. It means that the black wire is similar to the crack in the PVC veneer of the anti-static floor. The main anti-static material is conductive wire which is made of carbon wire. It shows black. Obviously, this is not the usual color we see. Actual demands of anti-static raised floor But the needs of customers determine the color of some anti-static products. For example, the anti-static platform may has blue, green and gray, especially green. It is good for people’s eyes to see for such a long time. These similar demands determine other products. The dust-free clean workshop usually uses

The Commonalities and Differences Between HPL and PVC
There are two main finish used in raised floor system. They are HPL (high pressure laminate) and PVC. Today we mainly compare the commonalities and differences between these two coverings. The Characteristics of HPL and PVC High pressure laminate is hard anti-static special fireproof board, which is made of phenolic and melamine resin treated with various special papers. And it is made of resin decorative laminate made of high temperature and high pressure. The use of nanotechnology in the resin to increase the anti-pollution, wear resistance and long-lasting static charge elimination characteristics. So it is a commonly used veneer in the anti-static floor industry. PVC coverings have long-lasting anti-static properties and stable electrical conductivity. It uses a conductive network formed by the interface of plastic particles with multiple patterns on the surface. The appearance resembles a marble pattern and has a good decorative effect. But its surface wear resistance is

Main Types of Anti-static Raised Floor
Our common anti-static raised floor types are mainly the following:anti static tile, high pressure laminate one, steel one, composite one and so on. Anti static tile On the basis of the preparation process of ordinary ceramic tiles, the green body and glaze layer add the anti-static functional powder. It makes the ceramic tiles have a stable resistance value, generally between 1.0 x 106——1.0 x 109 Ω. And workers do the construction conveniently without laying copper strip. At present, it is very popular in the market, but there are very few manufacturers in the Chinese market. High Pressure Laminate anti-static raised floor This floor uses high-strength, fire-proof and water-proof materials as the base material, double anti-static veneer. It has excellent waterproof and moisture-proof performance and strong bearing capacity. So large and medium-sized machine rooms usually use this type of raised floor. Steel anti-static raised floor Steel anti-static floor can has several types,

Necessary Raised Floor Installation Steps
As one of the standard equipment of modern office, the application range of network raised floor has become more and more extensive. It can save headroom more than traditional raised floors. And it is widely used in many large office spaces such as office buildings. Of course, in order to make the most of its product advantages, in the following content, we will introduce the correct raised floor installation steps for everyone. Installation steps one: Clean up the ground Clean up the ground before laying the raised floor. For example, clean up everything from the ground, including dust, dirt, and mud. If there are bumps on the ground, they must be filled or removed to keep the ground flat. Installation steps two: Measure the site The second step is estimation and ordering. The estimate is by definition to measure the site and estimate how many installation items are needed, such

The Difference Between PVC Plastic Floor and PVC Anti-static Floor
The main component of PVC plastic floor is polyethylene which is made of plastic. PVC anti-static floor is mainly PVC resin. From the application scope, plastic floor is generally used in families and businesses; anti-static floor is generally widely used in hospitals, stadiums, laboratories and other non-domestic spaces. PVC flooring is widely used in various places in homes and businesses due to its diverse colors. The PVC floor is actually a plastic floor. At present, the PVC floor on the market can be made into two categories, one is a homogeneous floor, the pattern material from the bottom to the surface is the same, this If the surface of the floor is damaged, it can be polished off with a sander and re-waxed. It looks like a new one. There is another type of compound, the top layer is a pure PVC transparent layer. Then add it below The upper

Why Raised Floor– The Reason You Choose It
Raised floor has been applied to industrial and commercial buildings for decades of years, and it is still very popular nowadays. It is irreplaceable in some particular occasion, because it does face the challenges and offer the solutions. What problems do we face Modern offices need to adapt different layouts with different users and lessees. Traditional facilities always become obsolete due to wiring and wiring distribution problems created by organisational changes and advances in technology. So building designers and facility managers need to face the challenges of constantly changing space needs. At the same time, they should keep their life-cycle costs down. In data centers, computer rooms and all places with large numbers of electronic devices. Owners need to find a way to eliminate the harmful effect on all their devices. So it can extend their service life. At the same time, huge and complicated wiring without the raised floor

What Ground Materials Are Commonly Used in Data Centers
According to the relevant provisions of GB 50222-95 code for fire protection design of interior decoration of buildings: the ground of large and medium-sized electronic computer room shall be decorated with materials no less than Class B1. The interior decoration of cylinder room and so on shall be decorated with class A materials. Due to the particularity of the data center, there are not many kinds of ground that can be used. The advice is as follows. Anti static raised floor for data center When the air conditioning system adopts the condition of upper and lower supply air, we usually use this kind of ground form. It is also the most commonly used one in the machine room. Static electricity will not only cause random failure of computer operation, but also lead to the destruction of some precision devices. In addition, when the static electricity is discharged to the computer,