Is Related between Performance and Color of Anti-static Raised Floor?
Is there an inevitable relationship between the performance and color of anti-static raised floor? Can the anti-static raised floor with such bright colors be effectively anti-static? Let us explore the principle of it. Anti-static principle In fact, for anti-static raised floor, the most important is the conductive wire embedded in it. It means that the black wire is similar to the crack in the PVC veneer of the anti-static floor. The main anti-static material is conductive wire which is made of carbon wire. It shows black. Obviously, this is not the usual color we see. Actual demands of anti-static raised floor But the needs of customers determine the color of some anti-static products. For example, the anti-static platform may has blue, green and gray, especially green. It is good for people’s eyes to see for such a long time. These similar demands determine other products. The dust-free clean workshop usually uses

The Commonalities and Differences Between HPL and PVC
There are two main finish used in raised floor system. They are HPL (high pressure laminate) and PVC. Today we mainly compare the commonalities and differences between these two coverings. The Characteristics of HPL and PVC High pressure laminate is hard anti-static special fireproof board, which is made of phenolic and melamine resin treated with various special papers. And it is made of resin decorative laminate made of high temperature and high pressure. The use of nanotechnology in the resin to increase the anti-pollution, wear resistance and long-lasting static charge elimination characteristics. So it is a commonly used veneer in the anti-static floor industry. PVC coverings have long-lasting anti-static properties and stable electrical conductivity. It uses a conductive network formed by the interface of plastic particles with multiple patterns on the surface. The appearance resembles a marble pattern and has a good decorative effect. But its surface wear resistance is

Main Types of Anti-static Raised Floor
Our common anti-static raised floor types are mainly the following:anti static tile, high pressure laminate one, steel one, composite one and so on. Anti static tile On the basis of the preparation process of ordinary ceramic tiles, the green body and glaze layer add the anti-static functional powder. It makes the ceramic tiles have a stable resistance value, generally between 1.0 x 106——1.0 x 109 Ω. And workers do the construction conveniently without laying copper strip. At present, it is very popular in the market, but there are very few manufacturers in the Chinese market. High Pressure Laminate anti-static raised floor This floor uses high-strength, fire-proof and water-proof materials as the base material, double anti-static veneer. It has excellent waterproof and moisture-proof performance and strong bearing capacity. So large and medium-sized machine rooms usually use this type of raised floor. Steel anti-static raised floor Steel anti-static floor can has several types,

Necessary Raised Floor Installation Steps
As one of the standard equipment of modern office, the application range of network raised floor has become more and more extensive. It can save headroom more than traditional raised floors. And it is widely used in many large office spaces such as office buildings. Of course, in order to make the most of its product advantages, in the following content, we will introduce the correct raised floor installation steps for everyone. Installation steps one: Clean up the ground Clean up the ground before laying the raised floor. For example, clean up everything from the ground, including dust, dirt, and mud. If there are bumps on the ground, they must be filled or removed to keep the ground flat. Installation steps two: Measure the site The second step is estimation and ordering. The estimate is by definition to measure the site and estimate how many installation items are needed, such

The Difference Between PVC Plastic Floor and PVC Anti-static Floor
The main component of PVC plastic floor is polyethylene which is made of plastic. PVC anti-static floor is mainly PVC resin. From the application scope, plastic floor is generally used in families and businesses; anti-static floor is generally widely used in hospitals, stadiums, laboratories and other non-domestic spaces. PVC flooring is widely used in various places in homes and businesses due to its diverse colors. The PVC floor is actually a plastic floor. At present, the PVC floor on the market can be made into two categories, one is a homogeneous floor, the pattern material from the bottom to the surface is the same, this If the surface of the floor is damaged, it can be polished off with a sander and re-waxed. It looks like a new one. There is another type of compound, the top layer is a pure PVC transparent layer. Then add it below The upper

Why Raised Floor– The Reason You Choose It
Raised floor has been applied to industrial and commercial buildings for decades of years, and it is still very popular nowadays. It is irreplaceable in some particular occasion, because it does face the challenges and offer the solutions. What problems do we face Modern offices need to adapt different layouts with different users and lessees. Traditional facilities always become obsolete due to wiring and wiring distribution problems created by organisational changes and advances in technology. So building designers and facility managers need to face the challenges of constantly changing space needs. At the same time, they should keep their life-cycle costs down. In data centers, computer rooms and all places with large numbers of electronic devices. Owners need to find a way to eliminate the harmful effect on all their devices. So it can extend their service life. At the same time, huge and complicated wiring without the raised floor

What Ground Materials Are Commonly Used in Data Centers
According to the relevant provisions of GB 50222-95 code for fire protection design of interior decoration of buildings: the ground of large and medium-sized electronic computer room shall be decorated with materials no less than Class B1. The interior decoration of cylinder room and so on shall be decorated with class A materials. Due to the particularity of the data center, there are not many kinds of ground that can be used. The advice is as follows. Anti static raised floor for data center When the air conditioning system adopts the condition of upper and lower supply air, we usually use this kind of ground form. It is also the most commonly used one in the machine room. Static electricity will not only cause random failure of computer operation, but also lead to the destruction of some precision devices. In addition, when the static electricity is discharged to the computer,

Accessories for Raised Floors — Pedestals
It seems that we only focus on the raised floor itself and overlap the function of the support. As an accessory supporting the raised floor, the pedestal plays a constant role. So how to choose the right pedestal when buying raised floors? The type of floor determines the pedestal There are different types of pedestals according to different types of flooring. For steel raised flooring and encapsulated raised floors, there are aluminum head pedestals and flat head pedestals. Anti-static raised floor is suitable for flat-head brackets and stringers. The difference between them is that we place stringers in different ways. The workers insert the stringers of calcium sulfate panels or wood core board into the pedestal. Load capacity requirements decides the brackets The general load-bearing is based on FS 800-1000, and it usually use a 25 * 1.2 mm pedestal. But if the load-bearing requirements are higher, a 22 *

Laying Method of Grounding Copper Strip for Anti-static Floor
Laying copper strip can make the anti-static place play a role stably. It works especially in the high-end machine room and data center which need high-precision control, equipment stability and data security. Before construction, confirm that the whole building has a good grounding and lightning protection system. There are usually two ways of laying copper strip. Cross paving to lay copper strip The first one is that laying the copper strip by the way of cross paving. Keep the distance between copper foils at about 1.2 m. Square the copper foil along the installation direction of the floor bracket. Connect the balance potential of the whole building with the copper foil, floor, bracket and crossbeam. Make the static electricity directly to the ground to release the static electricity. The laying should be smooth and straight. Because we should ensure that each node is closely contacted and the limit meets the

Preventing Electrostatic Hazards by Human Body
Causes of static electricity Static electricity is formed by the redistribution of charge caused by friction and the mutual attraction of charges. There are generally three conditions for human body to generate static electricity, one is air drying, the other is non-conductive chemical fiber clothing, and the third is weak constitution. Anti static principle To deal with static electricity, we can take “prevent static electricity” and “release static electricity”. We should try our best to choose pure cotton products as clothing fabrics and home accessories, and try to avoid using chemical fiber carpets and furniture with plastic as surface materials to prevent friction and electrification. Try to keep away from TV, refrigerator and other electrical appliances to prevent induction electrification. “Discharge” is to increase humidity, so that local static electricity is easy to release. Avoid long-term contact with computers, open windows when watching TV or computers, wash hands and face